From e6192f6f60d06f371d03e3b95b7214ee6f3ae4b5 Mon Sep 17 00:00:00 2001 From: Cristina Forde Date: Sun, 17 Aug 2025 02:35:12 +0000 Subject: [PATCH] Add 'HONOR Watch 4' --- HONOR-Watch-4.md | 9 +++++++++ 1 file changed, 9 insertions(+) create mode 100644 HONOR-Watch-4.md diff --git a/HONOR-Watch-4.md b/HONOR-Watch-4.md new file mode 100644 index 0000000..45c56e8 --- /dev/null +++ b/HONOR-Watch-4.md @@ -0,0 +1,9 @@ +
The data comes from the HONOR lab. With a spherical-nook design, the diagonal length of the display is 1.Seventy five inches when measured as a regular rectangle (the actual area of view is slightly smaller). The display's refresh rate is as much as 60Hz. The precise show might differ relying on different scenarios. Please consult with the acutal product. Product photos and display contents are provided for reference only, please confer with actual products for details. The HONOR Health APP needs to be installed to download the themed dials, iOS telephone does not help the paid dial download. Burn Fat Fast is simply accessible for Outdoor Run mode. This product isn't a medical device however is for well being management. The measured data and outcomes are for reference solely. This product isn't a medical device however is for [BloodVitals health](http://git.datanest.gluc.ch/vcuvenetta6416) management. The measured data and results are for reference solely. This operate is barely obtainable when the watch is paired with the telephone via Bluetooth.
+ +
Bluetooth Calling is barely available with Android 9.0 or higher model, and [BloodVitals SPO2](http://www.schopnost.cz/lavonbaecker8) iOS 11.0 or larger version. SMS quick reply is only supported by pairing with Android 9.Zero or higher version. Text customization and [BloodVitals SPO2](https://code.zwerer.com/syreetaseaman5) changing SMS text order aren't supported. The data comes from the HONOR Lab, under the condition of utilizing with HONOR telephone. The ends in precise purposes might differ as a result of surroundings, utilization habits, and other elements. Typical utility eventualities: enabling Continuous Heart Rate Measurement (Smart mode) and [BloodVitals health](https://systemcheck-wiki.de/index.php?title=Benutzer:EllieN97523) Healthy Sleep, making Bluetooth requires 30 minutes per week, playing music for 30 minutes per week, exercising for ninety minutes per week (GPS on), enabling notifications (50 messages, 6 incoming calls, three alarm clocks per day), brightening the display 200 times a day. The actual battery life varies relying on usage habits of customers. This product is just not a medical device however is for well being administration. The measured knowledge and outcomes are for reference solely. This product isn't a medical system however is for well being management. The measured information and outcomes are for reference solely, and do not function a foundation for prognosis or therapy. The characteristic blood oxygen ([BloodVitals SPO2](http://giggetter.com/blog/19399/bloodvitals-spo2-revolutionizing-home-blood-oxygen-monitoring/)) isn't out there in the markets of Chinese Taiwan, Japan and South Korea.
+ +
Certain constituents within the blood affect the absorption of gentle at numerous wavelengths by the blood. Oxyhemoglobin absorbs gentle extra strongly within the infrared area than in the purple region, whereas hemoglobin exhibits the reverse behavior. Therefore, highly oxygenated blood with a excessive concentration of oxyhemoglobin and a low focus of hemoglobin will are likely to have a excessive ratio of optical transmissivity within the purple region to optical transmissivity in the infrared region. These alternating portions are amplified after which segregated by sampling gadgets operating in synchronism with the purple/infrared switching, in order to offer separate alerts on separate channels representing the purple and [BloodVitals health](https://systemcheck-wiki.de/index.php?title=There_Is_An_Example_With_A_Red_Strap) infrared gentle transmission of the body construction. After low-pass filtering to take away signal elements at or above the switching frequency, each of the separate alerts represents a plot of optical transmissivity of the body structure at a particular wavelength versus time. AC element triggered solely by optical absorption by the blood and varying on the pulse frequency or heart charge of the organism.
+ +
Each such signal additionally includes an invariant or DC element associated to other absorption, equivalent to absorption by tissues other than blood within the physique structure. AC and DC components of these signals. IR" LED drive 24 are connected to LED's sixteen and 18 respectively. 26 is organized to actuate LED drives 22 and 24, and therefore LED's sixteen and 18, in response to a predetermined alternating sequence interspersed with darkish intervals. During every such darkish interval, the timing unit 26 deactivates the LED drives and hence deactivates each LED's. Thus, the LED drives and LED's provide alternating purple and infrared illumination, whereas the timing unit periodically interrupts this illumination to offer the darkish intervals. 34 is also supplied. Preamplification means 34 includes an operational amplifier 36 defining an inverting enter node 38, an output node forty and a non-inverting enter node forty two connected to floor. 46 samples the amplifier output signal at preamplifier output node forty and provides a sequence of samples to each signal processing channel.
+ +
While LED 16 is offering pink mild, the amplified sign obtained from preamplifier 34 is routed by means of swap 46 to red sign processing channel 48. Conversely, when infrared gentle is being emitted by diode 18, the amplified sign is routed to IR sign processing channel 50. During darkish intervals, whereas neither diode is operative, the amplified output sign just isn't routed to both signal processing channel. Each of sign processing channels forty eight and 50 might include generally typical parts for converting the periodic signal samples provided by means of swap 46 into a considerably steady, smoothed sign, eliminating spurious elements ensuing from the switching process itself and determining the AC and DC parts of the smoothed signal. 10 Hz, and is arranged to attenuate alerts above that frequency. Fifty two is linked to both sign processing channels 48 and 50, the microprocessor being organized to obtain digital values from the first and second analog to digital converter of every channel.